Per 29 CFR 1910.146 — Permit-Required Confined Spaces | EHS Community Template
| Potential Hazard | Present? (Y/N) | Control Measure |
|---|---|---|
| Oxygen-deficient atmosphere (<19.5%) | ||
| Oxygen-enriched atmosphere (>23.5%) | ||
| Flammable gas / vapor (>10% LEL) | ||
| Toxic air contaminant (above PEL) | ||
| Engulfment / flooding hazard | ||
| Internal configuration / entrapment | ||
| Mechanical / energized equipment | ||
| Thermal (heat / cold stress) | ||
| Other: _______________________ |
Before entry, test in this order: oxygen, then combustible gases and vapors, then toxic gases and vapors (29 CFR 1910.146(d)(5)(iii)). During entry, test or monitor as often as needed to confirm acceptable conditions are maintained (d)(5)(ii); monitor continuously where the space cannot be isolated (d)(5)(i). Continuous monitoring, and testing at several levels where the atmosphere may be stratified (Appendix B to 1910.146), are good practice. Column limits are US federal OSHA values; Cal/OSHA's are lower (8 CCR 5155: CO 25 ppm and H₂S 10 ppm 8-hour PELs) and Canadian provinces set their own, so use the limits for your jurisdiction.
| Time | Tested By | Instrument / Cal. Date | O₂ % (19.5–23.5%) | LEL % (<10%) | CO ppm (US PEL: 50, 8-hr TWA) | H₂S ppm (US ceiling: 20) | Other | Safe to Enter? |
|---|---|---|---|---|---|---|---|---|
| Role | Name (Print) | Signature | Time In | Time Out |
|---|---|---|---|---|
| Entry Supervisor | — | — | ||
| Attendant (Outside) | — | — | ||
| Authorized Entrant 1 | ||||
| Authorized Entrant 2 | ||||
| Rescue Service Contact | — | — | — |
Cancelled permits must be retained for at least 1 year per 29 CFR 1910.146(e)(6) so that failures can be reviewed during the annual review of the confined space program.